1.1 ,This test method covers the measurement of the penetration rate of the dynamic cone penetrometer with an 8-kg [17.6-lb] hammer (8-kg [17.6-lb] DCP) through undisturbed soil or compacted materials, or both. The penetration rate may be related to in situ strength such as an estimated in situ CBR (California Bearing Ratio). A soil density may be estimated (Note 1) if the soil type and moisture content are known. The DCP described in this test method is typically used for pavement applications.