1.1 ,This test method covers the determination of total oil and grease (TOG) that can be extracted from water or wastewater samples by cyclohexane and measured by non-dispersive IR spectroscopy from 1370–,1380 cm-1. Treating the extract with Florisil2 to remove polar substances prior to the IR measurement enables determination of the total petroleum (TPH).